Systematic review on sensitivity and specificity of rapid test kits for dengue detection / (Record no. 12252)

MARC details
000 -LEADER
fixed length control field 03091nam a22003617a 4500
001 - CONTROL NUMBER
control field MT 2022 0016
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240720153241.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220406b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging eng
Transcribing agency FEU-NRMF MEDICAL LIBRARY
Description conventions rda
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title english
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number MT 2022 0016
245 ## - TITLE STATEMENT
Title Systematic review on sensitivity and specificity of rapid test kits for dengue detection /
Statement of responsibility, etc. Mariella A. Baron, Ma. Flerida H. Benavides, Catherine Dhianne B. Lopez, Marviel Christine H. Santos, Ma. Bernadette S. Tejano; Rupert T. Vicencio.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. Fairview, Quezon City:
Name of publisher, distributor, etc. School of Medical Technology, FEU-NRMF,
Date of publication, distribution, etc. 2022.
300 ## - PHYSICAL DESCRIPTION
Extent 66 pages:
Other physical details illustrations, tables;
Dimensions 28 cm.
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes appendices and bibliographical references.
520 ## - SUMMARY, ETC.
Summary, etc. Abstract: Dengue virus is considered a public health concern worldwide. Due to rapid increase of dengue cases, the use of laboratory procedures such as the RT-PCR are not ideal due to the long turn-around-time causing delay in sample processing, leading to the delay of treatment. Thus, test kit capable of providing rapid yet accurate results are crucial for a quality clinical management. The application of the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) checklist is appropriate for this type of study which will guide the researchers to produce a significantly relevant paper. The study is curated through the review of various scholarly writings discussing the sensitivity and specificity rate of six (6) rapid test kits namely Humasis Dengue Combo NS1 & IgG/IgM Test, SD Bioeasy Dengue Duo, SD Bioline Dengue Duo NS1 Ag and IgM/IgG test, CareUs Dengue Combo NS1and IgM/IgG kits Panbio Dengue Duo Cassette and Dengue NS1 Ag Strip Bio-Rad. Through utilization of Google Scholar as the search engine, a total of 1,109 articles were relevant to the provided keywords. Out of the 1,109 only 34 articles were included which were distributed to the test kits in review. The specificity and sensitivity values from the scholarly writings designated for every test kit were tabulated and averaged to establish standard representative value for each kit which were compared to one another to determine which provides the highest performance for dengue detection. It is concluded that among the six (6) test kits the CareUs Dengue Combo NS1 and IgM/ IgG Kit exhibited the best performance as a dengue infection diagnostic tool through recognition of both antigen and antibodies specific to dengue in the venipuncture samples.
521 ## - TARGET AUDIENCE NOTE
Target audience note Thesis - School of Medical Technology
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element dengue virus
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element rapid test kits
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element sensitivity
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element specificity
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Baron, Mariella A.
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Benavides, Ma. Flerida H.
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Lopez, Catherine Dhianne B.
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Santos, Marviel Christine H.
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Tejano, Ma. Bernadette S.
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Vicencio, Rupert T., RMT
Relator term adviser
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Room Use
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Theses 04/06/2022   MT 2022 0016 c.1 T002319 04/06/2022 04/06/2022 Room Use  
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Theses 04/06/2022   MT 2022 0016 c.2 T002320 04/06/2022 04/06/2022 Room Use  
    Library of Congress Classification   Not For Loan Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation   06/24/2022   MT 2022 0016 c.3 T002321 06/24/2022 06/24/2022   forwarded to SMT