Comparative analytical turnaround time between manual and semi-automated methods for urine sediment analysis, (Record no. 13168)

MARC details
000 -LEADER
fixed length control field 03100nam a22003137a 4500
001 - CONTROL NUMBER
control field T002889
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20241030134547.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 241030b |||||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging eng
Transcribing agency FEU-NRMF MEDICAL LIBRARY
Modifying agency rda
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number MT 2024 0029 c.1
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Abad, Terri Lynne B.,
Relator term author
245 01 - TITLE STATEMENT
Title Comparative analytical turnaround time between manual and semi-automated methods for urine sediment analysis,
Remainder of title [author]: Abad, Terri Lynne B., Consulta, Mark Anthony D.C, Funcion, Jerricho G., Pena, Julien Angela A., Torrano, Angelica Marie T.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. Quezon City,Philippines;
Name of publisher, distributor, etc. FEU-NRMF Dr. Nicanor Reyes Medical Foundation Institute of Medicine,
Date of publication, distribution, etc. 2024
300 ## - PHYSICAL DESCRIPTION
Extent 105pages
Dimensions 28cm
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes Appendix
520 ## - SUMMARY, ETC.
Summary, etc. ABSTRACT:<br/>BACKGROUND: Assessing the Turnaround Time (TAT) in urine sediment analysis plays a critical role in speeding up clinical laboratory results availability thus affording clinicians faster diagnosis especially at the emergency department. This study involves a comparative analysis of the TAT for both manual and automated methods, each playing a distinct role in delivering<br/>accurate and timely results.<br/>METHOD: This study employs a cross-sectional comparative experimental design to assess the turnaround times in manual and automated urinalysis processes. Participants, within the age bracket of 18 to 60 years old, including medical technologists, will be recruited from a Tertiary Private Hospital.<br/>RESULT: The manual method group exhibited a mean analytical time of 1243 seconds (SD = 1194) and a standard error of 178. This variability may be attributed to a variety of factors. The automated method group's mean analytical time was 63.4 seconds (SD = 8.06), with a standard error of 1.20. The automated group's low standard deviation implies that automation produces<br/>more consistent results.<br/>CONCLUSION: Automated methods provide a substantial improvement in turnaround time and consistency compared to manual processes. Participants noted the ease of categorization and rapid results obtained through automated systems, with one participant stating that while manual analysis takes approximately 20-25 minutes per sample, automated systems can<br/>deliver results in as little as five minutes. This efficiency is critical for maintaining high standards in clinical laboratories, as inaccuracies in urine analysis can lead to misdiagnosis and inappropriate treatment.<br/>Keywords: automated method, comparative experimental design, manual method, turnaround<br/>time<br/>
521 ## - TARGET AUDIENCE NOTE
Target audience note School of Medical Technology
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Abad, Terri Lynne B.,
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Consulta, Mark Anthony D.C
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Funcion, Jerricho G.,
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Pena, Julien Angela A.,
Relator term author
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Torrano, Angelica Marie T.
Relator term author
856 ## - ELECTRONIC LOCATION AND ACCESS
Enable Ebook Yes
Text to speech No
Electronic format type pdf
Uniform Resource Identifier <a href="https://library.feu-nrmf.ph/cgi-bin/koha/opac-retrieve-file.pl?id=eeb4afddcb5fcaf871ec580044c748d7">https://library.feu-nrmf.ph/cgi-bin/koha/opac-retrieve-file.pl?id=eeb4afddcb5fcaf871ec580044c748d7</a>
Link text Click here for FULL TEXT
Permission ALL
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation 10/30/2024   MT 2024 0029 c.1 T002889 10/30/2024 10/30/2024 Theses
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation 10/30/2024   MT 2024 0029 c.2 T002890 10/30/2024 10/30/2024 Theses
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation 10/30/2024   MT 2024 0029 c.3 T002891 10/30/2024 10/30/2024 Theses