The seemingly impossible: A case report on using laryngeal mask airway in total thyroidectomy / (Record no. 13211)

MARC details
000 -LEADER
fixed length control field 01704nam a22002537a 4500
001 - CONTROL NUMBER
control field R000782
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20241111121108.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 241111b |||||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging eng
Transcribing agency FEU-NRMF MEDICAL LIBRARY
Description conventions rda
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number ANES 2024 0004
245 ## - TITLE STATEMENT
Title The seemingly impossible: A case report on using laryngeal mask airway in total thyroidectomy /
Remainder of title Katreena Camille C. Aquino
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. Fairview, Quezon City;
Name of publisher, distributor, etc. Department of Anesthesiology, FEU-NRMF,
Date of publication, distribution, etc. 2024
300 ## - PHYSICAL DESCRIPTION
Dimensions ( in folder )
Accompanying material with flash drive (soft copy)
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes bibliographical references
520 ## - SUMMARY, ETC.
Summary, etc. ABSTRACT:<br/>This is a case of 61-year-old male with multinodular nontoxic goiter who underwent total thyroidectomy under general anesthesia – laryngeal mask airway after multiple failed intubation attempts. The patient had a Cormack-Lehane grade of 4 under direct visualization. Despite changing operators, blade size and endotracheal tube sizes, intubation was not successful. A laryngeal mask airway device size 4 was then successfully inserted, with equal bilateral breath sound and successive end tidal waveform. There was no airway leakage, no desaturation nor dislodgment of the laryngeal mask airway device noted throughout the seven-hour thyroidectomy.<br/>Keyword: Difficult intubation, Laryngeal mask airway, thyroidectomy<br/>
521 ## - TARGET AUDIENCE NOTE
Target audience note Research - Department of Anesthesiology
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Katreena Camille C. Aquino
Relator term author
856 ## - ELECTRONIC LOCATION AND ACCESS
Enable Ebook Yes
Text to speech No
Electronic format type pdf
Uniform Resource Identifier <a href="https://library.feu-nrmf.ph/cgi-bin/koha/opac-retrieve-file.pl?id=0337cbfb6f0111ab30146ed8ec25ca30">https://library.feu-nrmf.ph/cgi-bin/koha/opac-retrieve-file.pl?id=0337cbfb6f0111ab30146ed8ec25ca30</a>
Link text Click here for FULL TEXT
Permission ALL
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Research
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation 11/11/2024   ANES 2024 0004 R000782 11/11/2024 11/11/2024 Research