Determination of the normal range of sizes of intra-abdominal lymphatic trunk using multi-detector row CT scan / (Record no. 7894)

MARC details
000 -LEADER
fixed length control field 02264nam a22002777a 4500
001 - CONTROL NUMBER
control field RAD 2010 0001
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240720152603.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160505b2010 xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging eng
Transcribing agency FEU-NRMF MEDICAL LIBRARY
Description conventions rda
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title english
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number RAD 2010 0001
245 ## - TITLE STATEMENT
Title Determination of the normal range of sizes of intra-abdominal lymphatic trunk using multi-detector row CT scan /
Statement of responsibility, etc. Honey Beth C.Medenilla, Ma. Lourdes S. Badion and Rodney B. Pidlaoan.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. Fairview, Quezon City:
Name of publisher, distributor, etc. Department of Radiology, FEU-NRMF,
Date of publication, distribution, etc. 2010.
300 ## - PHYSICAL DESCRIPTION
Other physical details illustration, photos;
Dimensions (in folder)
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes appendices and bibliographical references.
520 ## - SUMMARY, ETC.
Summary, etc. Abstract: To determine the normal range of sizes of intra-abdominal lymphatic ducts using multi-detector row CT scan. Multiplanar reconstructed images of two hundred sixty nine patients who underwent diagnostic abdominal imaging and periodic screening presumed to be healthy were reviewed by three radiologist individually for the normal range of sizes of intra-abdominal lymphatic trunks. The widest transverse diameter of the intra-abdominal lymphatic duct at the left paraaortic at the level of the renal hilum were measured and recorded. The average measurement of the three radiologists was analyzed using the Z-test. A total of 269 abdominal CT scan studies of patients with ages 17 - 87 years old were studied. Overall, among the three radiologists the normal range of lymphatic duct is 3.10 to 6.60 mm constituting 95% confidence interval. Among the female and male patients, the normal range is 2.89 to 6.60 mm and 3.18 to 6.64 mm, respectively. Both measurements constitute the 95% confidence interval. The normal range of intra-abdominal lymphatic ducts is 3.10 to 6.60 mm in our study. There is no significant difference in the size of the lymphatic duct among male and female patients.
521 ## - TARGET AUDIENCE NOTE
Target audience note Research - Department of Radiology
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Medenilla, Honey Beth C., MD.
Relator term principal investigator
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Badion, Ma. Lourdes S., MD.
Relator term supervising investigator
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Pidlaoan, Rodney B., MD.
Relator term co-supervising investigator
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Room Use
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Research 02/11/2015   RAD 2010 0001 c.1 R000262 03/01/2016 07/22/2016 Room Use  
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Research 02/11/2015   RAD 2010 0001 c.2 R000302 03/01/2016 07/22/2016 Room Use  
    Library of Congress Classification   Not For Loan Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Research 09/04/2019   RAD 2010 0001 R000657 09/04/2019 09/04/2019 Research draft