MARC details
000 -LEADER |
fixed length control field |
02264nam a22002777a 4500 |
001 - CONTROL NUMBER |
control field |
RAD 2010 0001 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
PILC |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20240720152603.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
160505b2010 xxu||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Language of cataloging |
eng |
Transcribing agency |
FEU-NRMF MEDICAL LIBRARY |
Description conventions |
rda |
041 ## - LANGUAGE CODE |
Language code of text/sound track or separate title |
english |
050 ## - LIBRARY OF CONGRESS CALL NUMBER |
Classification number |
RAD 2010 0001 |
245 ## - TITLE STATEMENT |
Title |
Determination of the normal range of sizes of intra-abdominal lymphatic trunk using multi-detector row CT scan / |
Statement of responsibility, etc. |
Honey Beth C.Medenilla, Ma. Lourdes S. Badion and Rodney B. Pidlaoan. |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) |
Place of publication, distribution, etc. |
Fairview, Quezon City: |
Name of publisher, distributor, etc. |
Department of Radiology, FEU-NRMF, |
Date of publication, distribution, etc. |
2010. |
300 ## - PHYSICAL DESCRIPTION |
Other physical details |
illustration, photos; |
Dimensions |
(in folder) |
336 ## - CONTENT TYPE |
Content type term |
text |
Source |
rdacontent |
337 ## - MEDIA TYPE |
Media type term |
unmediated |
Source |
rdamedia |
338 ## - CARRIER TYPE |
Carrier type term |
volume |
Source |
rdacarrier |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc |
Includes appendices and bibliographical references. |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Abstract: To determine the normal range of sizes of intra-abdominal lymphatic ducts using multi-detector row CT scan. Multiplanar reconstructed images of two hundred sixty nine patients who underwent diagnostic abdominal imaging and periodic screening presumed to be healthy were reviewed by three radiologist individually for the normal range of sizes of intra-abdominal lymphatic trunks. The widest transverse diameter of the intra-abdominal lymphatic duct at the left paraaortic at the level of the renal hilum were measured and recorded. The average measurement of the three radiologists was analyzed using the Z-test. A total of 269 abdominal CT scan studies of patients with ages 17 - 87 years old were studied. Overall, among the three radiologists the normal range of lymphatic duct is 3.10 to 6.60 mm constituting 95% confidence interval. Among the female and male patients, the normal range is 2.89 to 6.60 mm and 3.18 to 6.64 mm, respectively. Both measurements constitute the 95% confidence interval. The normal range of intra-abdominal lymphatic ducts is 3.10 to 6.60 mm in our study. There is no significant difference in the size of the lymphatic duct among male and female patients. |
521 ## - TARGET AUDIENCE NOTE |
Target audience note |
Research - Department of Radiology |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Medenilla, Honey Beth C., MD. |
Relator term |
principal investigator |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Badion, Ma. Lourdes S., MD. |
Relator term |
supervising investigator |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Pidlaoan, Rodney B., MD. |
Relator term |
co-supervising investigator |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Library of Congress Classification |
Koha item type |
Room Use |