VALIDATION STUDY OF DIGITAL SPHYGMOMANOMETER AS BLOOD PRESSURE MONITORING DEVICE (Record no. 8858)

MARC details
000 -LEADER
fixed length control field 03099nam a22004097a 4500
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240720152719.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160505b2007 xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Transcribing agency FEU-NRMF MEDICAL LIBRARY
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title English
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number MCFM20070008
245 ## - TITLE STATEMENT
Title VALIDATION STUDY OF DIGITAL SPHYGMOMANOMETER AS BLOOD PRESSURE MONITORING DEVICE
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. QUEZON CITY
Name of publisher, distributor, etc. FEU-NRMF
Date of publication, distribution, etc. 2007
300 ## - PHYSICAL DESCRIPTION
Extent 20 PAGES
520 ## - SUMMARY, ETC.
Summary, etc. ABSTRACT: Blood Pressure is an important sign of life. It may also reflect the presence of certain illnesses. Therefore, accurate measurement of this essential and foremost concern in the selection of an appropriate sphygmomanometer. In the past year, mercury and aneroid sphygmomanometers have been the primary tool in blood pressure measurement. With the advancement in technology, digital type of sphygmomanometer was introduced for people who seek convenience and lack skills to the traditional sphygmomanometer. Mercury containing devices have been linked to numerous environmental and health hazards. Finding an alternative that will closely measure blood pressure as compared to mercury sphygmomanometer has been the subjects of many hospitals and institutions. The study aims to validate digital sphygmomanometer (OMRON SEM-1) as an alternative for mercury containing sphygmomanometer. A blind selection of subjects was performed on 18 years old and above. Two blood pressure readings for each participant will be measured by two investigators using digital and mercury sphygmomanometer. The average blood pressure measurement for each type of sphygmomanometer will be computed and recorded. The specificity, sensitivity, % false positive, % false negative, predictive value of positive, predictive value of negative and correlation of blood pressure readings of digital (OMRON SEM-1) and mercury sphygmomanometer readings will be determined based on the results. Results of the study showed that OMROM SEM - 1 is not a good alternative for mercury sphygmomanometer clinically because it lacks in sensitivity compared to standard may be due to the fundamental calibration problem in measuring diastolic blood pressure. However, it can be used as a home unit monitoring device in patients who are known hypertensive because it has a high specificity especially for systolic blood pressure measurement.
521 ## - TARGET AUDIENCE NOTE
Target audience note Department of Community & Family Medicine
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name AQUINO, ELOISA REI S.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name BAHJIN, DELMAR S.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name BAHJIN, DELMAR S
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name CHUA, BENJAMIN U. III
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name DE LA CERNA, ERNEST M. JR.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name DE VERA, GERALYN M.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name DIZON, HENEDINE GAE B.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name JIMENEZ, ANNA MARIE A.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name MABASA, JENALYNN B.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name MAGNAYE, BERNADETTE E.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name MORALES, JUAN CARLOS R.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name MUNOZ, GEMMA S.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name PALISOC, MARIE ERNESTINE P
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name QUINTO, ARLENE L.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name SALAZAR, NINEL L
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name TIGLAO, EDGARDO D.C. JR.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name VIRIL, NANETTE C.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name WILLIS, ROCKY DANILO S.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name YAP, MARY FLOR JOY Q
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Theses
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Library of Congress Classification     Far Eastern University - Nicanor Reyes Medical Foundation Far Eastern University - Nicanor Reyes Medical Foundation Theses 02/11/2015   MCFM20070008 T000679 02/11/2015 07/22/2016 Theses