Image from Google Jackets

Evaluation of the accuracy of the multiple parameter scoring system in predicting fetal maturity among parturients 28-42 weeks and those for elective cesarean section at Far Easterm University-Dr. Nicanor Reyes Medical Foundation Medical Center / Audrey Harriette D. Agbuya, Lylah D. Reyes and Joseph U. Olivar.

Contributor(s): Language: english Publication details: Fairview, Quezon City: Department of Obstetrics and Gynecology, FEU-NRMF, 2010.Description: 36 pages: illustrations; (in folder)Content type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): LOC classification:
  • OB 2010 0003
Summary: Abstract: To determine the accuracy of the Multiple Parameter Scoring System in predicting fetal maturity. The study was conducted at a university-based hospital. It is a prospective cross-sectional study where all participants underwent ultrasonography using the Multiple Parameter Scoring System upon admission at the labor room. Findings were confirmed with the Final Ballard Score. There were 117 participants, majority at term pregnancy. The Multiple Parameter Scoring System has a sensitivity of 100% (95% Cl 96.48 to 99.92%), specificity of 85% (95% Cl 56.34 to 97.42%), positive predictive value of 98% and the negative predictive value of 100%. Likelihood ratios for a term fetus increased the post-test probability of more than 6 fold, giving it moderate accuracy. (95% Cl 2.49 to 24.82). The Multiple Parameter Scoring System is a useful diagnostic tool for predicting fetal maturity. It in moderately accurate but must be used with an understanding of its limitations.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Status Notes Date due Barcode
Research Far Eastern University - Nicanor Reyes Medical Foundation Research OB 2010 0003 (Browse shelf(Opens below)) Not For Loan draft R000652
Room Use Far Eastern University - Nicanor Reyes Medical Foundation Research OB 2010 0003 (Browse shelf(Opens below)) Available R000214

Includes appendices and bibliographical references.

Abstract: To determine the accuracy of the Multiple Parameter Scoring System in predicting fetal maturity. The study was conducted at a university-based hospital. It is a prospective cross-sectional study where all participants underwent ultrasonography using the Multiple Parameter Scoring System upon admission at the labor room. Findings were confirmed with the Final Ballard Score. There were 117 participants, majority at term pregnancy. The Multiple Parameter Scoring System has a sensitivity of 100% (95% Cl 96.48 to 99.92%), specificity of 85% (95% Cl 56.34 to 97.42%), positive predictive value of 98% and the negative predictive value of 100%. Likelihood ratios for a term fetus increased the post-test probability of more than 6 fold, giving it moderate accuracy. (95% Cl 2.49 to 24.82). The Multiple Parameter Scoring System is a useful diagnostic tool for predicting fetal maturity. It in moderately accurate but must be used with an understanding of its limitations.

Research - Department of Obstetrics & Gynecology

There are no comments on this title.

to post a comment.