Image from Google Jackets

Interrater reliability test of digitalized telescoping goniometer to measure actice range of motion of selected large joints among health individuals / Nadine Aguilar, Neil Alamillo, John Ambag, Raiviel Ambrocio, Jessa Buenagua, Pamela Caguiat; Er Dador Petil; Kenneth Mutia.

Contributor(s): Language: english Publication details: Fairview, Quezon City: School of Physical Therapy, FEU-NRMF, 2020.Description: 46 pages: illustrations, tables, photos; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
LOC classification:
  • PT 2020 0006
Summary: Abstract: The digitalized telescoping goniometer is an innovative tool to measure range of motions in the shoulder, elbow, hip, and knee wherein errors of measurements are diminished, such as determining the values through visual estimation and assuming landmark placement, which is essential to achieve accurate measurements. The aim of this study was to determine the inter-rater reliability of the digitalized telescoping goniometer in measuring active range of motion of selected Large Joints among Healthy Individuals. A total of 10 students from the school of Physical Therapy were chosen as participants for the pilot test was done to establish the reliability of the device in measuring AROM of shoulder, elbow, hip, and knee joints. A total of 25 healthy individuals within legal age from the Future Point 3 Condominium were conveniently chosen as the participants wherein their AROM of Shoulder, Elbow, Hip and Knee joints were assessed with both the digitalized telescoping goniometer and universal goniometer for one trial with the measurements of AAOS as the basis. ICC and LOA were used as the statistical tool in measuring the inter-rater reliability of the digitalized telescoping goniometer. The results showed that the Digitalized Telescoping Goniometer was statistically significant with acceptable ICC on seven range of motion; based on the 95% Confidence Interval of ICC, six on Shoulder joint namely: Right Shoulder Flexion, Left Shoulder Adduction, Right and Left Shoulder Internal Rotation, Right and Left Shoulder External Rotation. One on Knee joint namely: Right knee Extension. Poor ICC was recorded on seven ranges of motion namely: Left Shoulder Extension, Left Elbow Flexion, Left Hip Extension, Right Hip Adduction, Right Hip External Rotation and Right Knee Flexion, hence; we accept the null hypothesis on these motions based on the 95% Confidence Interval of ICC while the other remaining 18 months were interpreted as inconclusive for reliability hence; we accept the null on these motions based on the 95%Confidence Interval of ICC. The results indicated that the device was unreliable in measuring Range of Motion. With 25 motions showing poor or inconclusive reliability and only 7 motions showed statistically significant acceptable reliability across the two therapist.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Status Date due Barcode
Room Use Far Eastern University - Nicanor Reyes Medical Foundation Theses PT 2020 0006 (Browse shelf(Opens below)) Available T002364
Browsing Far Eastern University - Nicanor Reyes Medical Foundation shelves, Shelving location: Theses Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
PT 2020 0003 The Correlation between the domains of montreal cognitive assessment questionnaire - Philippines (MOCA-P) and stroke related factors among patients 3-6 months post-cerebral stoke in tertiary hospitals in Quezon City : a pilot study / PT 2020 0004 A Descriptive study about the perceptions of senior high school students of Far Eastern University - Nicanor Reyes Medical Foundation about physical therapy as a profession compared to other health care professionals / PT 2020 0005 A Descriptive study on the quality of life of patients with chronic stroke receiving conventional physical therapy approach rehabilitation / PT 2020 0006 Interrater reliability test of digitalized telescoping goniometer to measure actice range of motion of selected large joints among health individuals / PT 2023 0001 c.1 Utilization of smartphone applications for assessment of range of motion for clinical practice : a scoping review / PT 2023 0001 c.2 Utilization of smartphone applications for assessment of range of motion for clinical practice : a scoping review / PT 2023 0002 c.1 Perception and attitude of FEU-NRMF medicine and health allied students towards the role of FEU-NRMF guidance and counseling services in mental health and academic distress : a correlational study /

Includes appendices and bibliographical references.

Abstract: The digitalized telescoping goniometer is an innovative tool to measure range of motions in the shoulder, elbow, hip, and knee wherein errors of measurements are diminished, such as determining the values through visual estimation and assuming landmark placement, which is essential to achieve accurate measurements. The aim of this study was to determine the inter-rater reliability of the digitalized telescoping goniometer in measuring active range of motion of selected Large Joints among Healthy Individuals. A total of 10 students from the school of Physical Therapy were chosen as participants for the pilot test was done to establish the reliability of the device in measuring AROM of shoulder, elbow, hip, and knee joints. A total of 25 healthy individuals within legal age from the Future Point 3 Condominium were conveniently chosen as the participants wherein their AROM of Shoulder, Elbow, Hip and Knee joints were assessed with both the digitalized telescoping goniometer and universal goniometer for one trial with the measurements of AAOS as the basis. ICC and LOA were used as the statistical tool in measuring the inter-rater reliability of the digitalized telescoping goniometer. The results showed that the Digitalized Telescoping Goniometer was statistically significant with acceptable ICC on seven range of motion; based on the 95% Confidence Interval of ICC, six on Shoulder joint namely: Right Shoulder Flexion, Left Shoulder Adduction, Right and Left Shoulder Internal Rotation, Right and Left Shoulder External Rotation. One on Knee joint namely: Right knee Extension. Poor ICC was recorded on seven ranges of motion namely: Left Shoulder Extension, Left Elbow Flexion, Left Hip Extension, Right Hip Adduction, Right Hip External Rotation and Right Knee Flexion, hence; we accept the null hypothesis on these motions based on the 95% Confidence Interval of ICC while the other remaining 18 months were interpreted as inconclusive for reliability hence; we accept the null on these motions based on the 95%Confidence Interval of ICC. The results indicated that the device was unreliable in measuring Range of Motion. With 25 motions showing poor or inconclusive reliability and only 7 motions showed statistically significant acceptable reliability across the two therapist.

Thesis - School of Physical Therapy

There are no comments on this title.

to post a comment.